Welcome to your FP101 Quiz Enter your name Enter your email address 1. Penetrations in fire rated assemblies must follow: Engineering judgements Caulk and walk Approved fire stop system The contractors decision None 2. A smoke detector is allowed to be placed within 4" of the corner of the wall. True False None 3. Smoke detectors shall be placed no more than 3 feet from return air. True False None 4. Per NFPA 72 standard spacing for smoke detectors is: 10 feet 20 feet 30 feet 40 feet None 5. Heat detectors can be installed in an outdoor environment. True False None 6. Pull stations are required to be located: 2 feet from exit paths 2 feet from entrance to exit 5 feet from entrance path 5 feet from entrance to exit None 7. Addressable devices: Can help provide the location of the fire Can help provide the location of the building address Are on IDC Are not allowed per NFPA 72 None 8. Detectors that are not easily accessible must have: Access to provide for services Remote LED Remote means to test the unit All of the above None of the above None 9. The spacing in the standard can be used instead of the spacing stated in cut sheet by manufacturer. True False Sometimes None 10. NFPA 72 overrides requirements of the building code. True False None 11. Notification appliances: Detect fire Call the firefighters Alert occupants Help suppress fire None 12. At minimum intelligibility must be met for 15dbA above average sound level. True False None 13. Intelligibility must be measured. True False None 14. To meet performance objective for strobe, the minimum lumens/ft² shall be: 0.0375 0.0735 0.537 0.357 None 15. Which of the following needs to have visual coverage? Storage Room Closet Breakroom Private Office All of the above None of the above None 16. Which of the following needs to have audio coverage? Storage Room Closet Breakroom Private Office All of the above None of the above None 17. Doubling a distance from speaker results in a loss of: 3dBa 4dbA 5dbA 6dBa None 18. To increase intelligibility, you must have speakers spaced: Closer together with low watt tap Closer together with high watt tapp Father apart with low watt tap Father apart with high watt tap None 19. Audio coverage is required in all common areas, except private offices. True False None 20. A strobe: Must be seen by all viewers Must create an effect that catches the attention of the viewer Must be heard 15dba above ambient Does not need to be synchronized in a corridor None 21. Elevator recall: Returns power to the elevator Allows fire fighters to manually recall elevator Recalls elevator upon smoke detection from sprinkler room Recalls elevator automatically upon smoke detection from lobby detector None 22. Shunt trip: Shuts elevator door Kills power to elevator cab Kills power to elevator control panel Kills power to the brakes None 23. When a water flow device is used, shunt occurs: Immediately After 10 seconds After 20 seconds After 1 minute None 24. Temperature of a heat detector and sprinkler heads must be the same. True False None 25. NFPA 72 is the governing code for elevator recall. True False None 26. A smoke detector for recall is best suitable in: An open garage An unconditioned shaft All of the above None of the above None 27. Detectors in an elevator lobby must be: 11 feet from the elevator door 21 feet from the elevator door 31 feet from the elevator door 1 foot from the elevator door None 28. For elevator recall, if the building does not have a FA system, then the entire building needs to add a fire alarm device. True False None 29. Heat detector for shunt must be placeed ________ of the sprinkler head 12" 24" 36" 42" None 30. It is acceptable to use magnets to test smoke detectors. True False None Time's up